ISO tank container for sale

ISO tank containers for sale are special containers used for transporting bulk cargoes such as liquids and gases. They are designed and manufactured in accordance with the standards set by the International Organization for Standardization (ISO), which ensure the compatibility and safety of tank containers world wide.

Description

ISO tank container for sale

UN T11 Portable 26000L Large Volume SUS 316L 20ft ISO Tank Container Price

 

Product parameters:
PECIFICATION NO : FF3A-26-T11-L4BN-SPIC-P21067
TANK TYPE Full Frame T11 UN Portable tank
1.    General Parameters

1.1         Design Code  ASME VIII DIV. 1 / EN 14025
1.2         Maximum Gross Mass  36000  kg
1.3         Nominal Capacity 26000  litre (0, – 1.5%)
1.4        Vessel Design Temperature -40°C  to +150 °C
1.5         Maximum Product Loading Temperature (atm .)  150    °C
1.6         Maximum Allowable Working Pressure4.0     bar
Hydrostatic Test Pressure  6.0     bar
Maximum External Pressure  0.41    bar
1.7        Tare Mass 3560   kg (± 3%)
1.8         Frame (length / width / height)  6058 / 2438 / 2591mm

2.   Tank Details

2.1 Shell Material

Thickness

Finish

Material

Thickness

Finish

SANS 50028-7 Type 1.4402/1.4404 (C≤0.03%)
Equivalent to 316L      316L
Minimum calculated thickness: 4.2mm
Corrosion allowance: 0.2mm
Manufacture Thickness: 4.4mmSANS 50028-7 Type 1.4402/1.4404 (C≤0.03%)
Equivalent to 316L      316L
Minimum calculated thickness: 4.7mm
Corrosion allowance: 0.2mm
Manufacture Thickness: 4.9mm (after forming)
Hot or Cold Rolled and polished with 120 grit
2.2 Ends
2.3        Welds  Shell Longitudinal: as welded.
Circular: As welded, Bottom 400mm flush and polished (120grit).
Ground flush and polished with 120 grit .3-off stainless steel channel section.
2.4         Stiffening Rings
2.5         Radiography

2.6         Steam Heating

As per code requirements
8-off longitudinal runs steam heating system on barrel.
The longitudinal steam runs manufactured from stainless steel.
The steam heating connectors will be 304 grade .
The tank vacuum rings not used for steam heating.
1” BSP inlet, 1” BSP outlet both with captive caps and cable.
4 bar working pressure, 6 bar test with warning decals and
markings. A 3/8” condensate drain ball is fitted at the lowest
position of the outlet.Rockwool (50kg/m³) 50mm thick on aluminium foil.1.8mm GRP prepainted White (RAL9010) with lapped joints.
Seal provided by sealant.
10mm drain hole per panel on bottom centreline.
2.0mm thick GRP one piece end (RAL 9010).

2-off Stainless steel 304 2.0mm thick boxes fitted.
Front spillbox contains manhole and safety relief.
Rear spillbox contains air inlet and top discharge provision.
Each box is equipped with 2-off DN25 surface mounted PVC
drain tubes fitted to opposite end of box.
No lids fitted but provision for future fitting is provided.

One stainless steel 304 1.5mm thick bottom valve cabinet is
fitted around the bottom discharge assembly.
No Lid and bottom plate to be fitted.。

2.7         Insulation    Shell
Ends2.8         Cladding      ShellEnds

2.9         Spillbox

2.10      Bottom Valve cabinet
3.    Frame Details

3.1        Type

Full frame beam design ISO 1496/3 (1CC) without saddles. Front
and rear frame with lowered horizontal bottom crossmembers.

SPA-H or equivalent. SPA-H

ISO 1161 8-off in total.

3.2         Material

3.3         Corner castings

3.4        Top rails

3.5         Protection   Top
Bottom
3.6         Ladder

Integral in frame design.

4-off per tank, 1 per corner on top rail and header.
Raised bottom rail, lowered front and rear sill.

300mm wide Stainless steel 304 ladder, fitted to the rear end
right hand side. Ladder rungs to be antislip type. Fasteners to be
stainless steel welded to prevent theft..

1-off full length longitudinal and 2-off transverse 475mm wide
aluminium type(F-style). Walkway supported off spillboxes and
end frames using stainless steel fastenings with nuts.

3.7        Walkway
3.8         Earthing Protection             1-off stainless steel lug fitted to rear end bottom of frame.
3.9         Painting                                Carbon steel shotblasted to Sa 2½ profile
First layer       Epoxy zinc rich primer                             30 microns min DFT
Second layer  Epoxy primer                                           40 microns min DFT
Final layer      Acrylic                                                      50 microns min DFT
Total                                                                               120 microns min DFT
Colour             Blue (RAL 5002)
4.   Tank Fittings

4.1         Manhole

1-of 500mm low profile, 8 point fixing with brass handnuts and
TIR-locking. Gasket: Composite seal with PTFE outer
encapsulating EPDM inner.1-of.
DN80 flanged Supermaxi Highflow, without flameproof gauze.
Pressure only model set at +4.4 bar (63.8psi).
Provisional space for the future fitting of a bursting disc and
pressure gauge.
The assembly is situated off centre on a tangential tank pad.
Tank pad to be single drilled: 4xM16 on 152.4 PCD .
4.2         Safety Relief Assembly
4.3        Air Inlet assembly 1-of DN 40 ball valve terminating with 1½” BSP connection
and cap. The assembly is situated off centre on a tangential
tank pad.  Tank pad to be single drilled: 4xM10 on 103.4PCD.1-off  DN80 stainless steel tank pad fitted with a blind flange .
Siphon tube support bracket to be fitted on tank bottom .
The assembly is fitted off centre on a recessed horizontal tank pad.
Tank pad to be dual drilled: 6xM12 on 168PCD and 4xM16 on
160PCD.

1-of  DN80 45° hi-lift Footvalve and 3” clamped butterfly vale
terminating with a 3” BSP spigot with cap and chain.
Tank pad to be single drilled: 8xM12 on 177.8PCD.

A plastic coated stainless steel cable is fitted to the entire length of
the right hand side of the tank . 1-off emergency decals are fitted
above the cable .

Not fitted. Provision for a fusible link is fitted to the remote control
cable.

A surface mounted analogue type is fitted on rear GRP end left
hand side of the tank . Dual scale -40°C to + 160°C / -40°F to 320°F.
The thermometer is fitted with a protection bar.

A clear plastic document holder ø 110mm is fitted to the rear right
hand side beam . A drain hole is provided at the lowest point.

One set of mandatory decals is fitted . Customer logo supplied  and
fitted by manufacturer.

One set of stainless steel single language data plate is provided
stating the requirements as per the code.

4.4        Top Discharge Prov.
4.5         Bottom Discharge
4.6         Remote Control
4.7         Fusible Link
4.8        Thermometer
4.9         Document holder
4.10      Decals
4.11      Data Plates
4.12 Calibration A calibration plate marked in cm/litres is fitted on the front spillbox
side wall adjacent to the manhole. No calibrated stainless steel
grade dipstick and bracket fitted

Liquid storage tank container is widely used in industries for liquid transportation

on the road/ rail/ ship and storage.ISO tank container:
1. Inner layer – made of 6 or 8 mm thick Q235-B steel plate, compared with

ordinary 5 mm thick single-layer tank, the strength is greatly improved;
2.Outer layer – tempered glass fiber thickness of 4.0mm or more,

good compressive and seismic resistance. It has strong corrosion

resistance and corrosion resistance.
Unique technology is adopted between the inner and outer layers

to make it reach a gap of 0.1-1mm, so as to eliminate hidden dangers from the root.
Leak detector 24 hours to monitor, to prevent leakage caused by security risks.

 

Product pictures:

 

UN T11 Liquid Tank Container 20ft 25000L ISO Tank Shipping SUS 316L 1